Email: helpdesk@telkomuniversity.ac.id

This Portal for internal use only!

  • My Download
  • Checkout
Application Package Repository Telkom University
All Categories

All Categories

  • IBM
  • Visual Paradigm
  • Adobe
  • Google
  • Matlab
  • Microsoft
    • Microsoft Apps
    • Analytics
    • AI + Machine Learning
    • Compute
    • Database
    • Developer Tools
    • Internet Of Things
    • Learning Services
    • Middleware System
    • Networking
    • Operating System
    • Productivity Tools
    • Security
    • VLS
      • Office
      • Windows
  • Opensource
  • Wordpress
    • Plugin WP
    • Themes WP
  • Others

Search

0 Wishlist

Cart

Categories
  • Microsoft
    • Microsoft Apps
    • Office
    • Operating System
    • VLS
    • Developer Tools
    • Productivity Tools
    • Database
    • AI + Machine Learning
    • Middleware System
    • Learning Services
    • Analytics
    • Networking
    • Compute
    • Security
    • Internet Of Things
  • Adobe
  • Matlab
  • Google
  • Visual Paradigm
  • WordPress
    • Plugin WP
    • Themes WP
  • Opensource
  • Others
More Categories Less Categories
  • Get Pack
    • Product Category
    • Simple Product
    • Grouped Product
    • Variable Product
    • External Product
  • My Account
    • Download
    • Cart
    • Checkout
    • Login
  • About Us
    • Contact
    • Forum
    • Frequently Questions
    • Privacy Policy
  • Forum
    • News
      • Category
      • News Tag

iconTicket Service Desk

  • My Download
  • Checkout
Application Package Repository Telkom University
All Categories

All Categories

  • IBM
  • Visual Paradigm
  • Adobe
  • Google
  • Matlab
  • Microsoft
    • Microsoft Apps
    • Analytics
    • AI + Machine Learning
    • Compute
    • Database
    • Developer Tools
    • Internet Of Things
    • Learning Services
    • Middleware System
    • Networking
    • Operating System
    • Productivity Tools
    • Security
    • VLS
      • Office
      • Windows
  • Opensource
  • Wordpress
    • Plugin WP
    • Themes WP
  • Others

Search

0 Wishlist

Cart

Menu
  • Home
    • Download Application Package Repository Telkom University
    • Application Package Repository Telkom University
    • Download Official License Telkom University
    • Download Installer Application Pack
    • Product Category
    • Simple Product
    • Grouped Product
    • Variable Product
    • External Product
  • All Pack
    • Microsoft
      • Operating System
      • Productivity Tools
      • Developer Tools
      • Database
      • AI + Machine Learning
      • Middleware System
      • Networking
      • Compute
      • Security
      • Analytics
      • Internet Of Things
      • Learning Services
    • Microsoft Apps
      • VLS
    • Adobe
    • Matlab
    • WordPress
      • Themes WP
      • Plugin WP
    • Google
    • Opensource
    • Others
  • My account
    • Download
    • Get Pack
    • Cart
    • Checkout
  • News
    • Category
    • News Tag
  • Forum
  • About Us
    • Privacy Policy
    • Frequently Questions
    • Contact
Home/Matlab/Why do I see huge voltage spikes at the output of a 3 phase MMC (Modular multi-level converter) in Simscape, when the number of submodules >1, but not with 1 submodule?

Why do I see huge voltage spikes at the output of a 3 phase MMC (Modular multi-level converter) in Simscape, when the number of submodules >1, but not with 1 submodule?

PuTI / 2025-01-11
Why do I see huge voltage spikes at the output of a 3 phase MMC (Modular multi-level converter) in Simscape, when the number of submodules >1, but not with 1 submodule?
Matlab News

Dear Community,
I have a three phase bi-directional power converter modelled by the Simscape block Modular Multilevel Converter (MMC) set for full bridges. This is controlled by a sinusoidal PWM generator and includes a simple LC filter to filter the inverter’s output and help me see a sine wave at the output. The DC Source is a battery with 1000V. The reference setpoint to the PWM generator is a three phase sine wave generator multiplied with a manual gain block (= 0.565) at the moment (this open loop is intentional while I focus on building the plant model at the moment, and will move on to closed loop controller development in next stages).
My model & parameter file is attached.
In the MMC, when the number of submodules = 1 the inverter output and the filtered output waveforms are as expected. (Image below).

However, when I set number of submodules = 2 or above the inverter output (before being filtered) has huge voltage spikes. The filter manages to smoothen these spikes somewhat but I would like to understand why do the spikes show up at Nsm = 2,3, etc and not at Nsm = 1?

A zoomed in view of the phase-to-phase voltage confirms that the inverter is doing it’s job as expected, just with the addition of very high voltage spikes.

Other things I have considered/ tried:
I. Filter Design
For a considerable duration while working with Nsm = 2, I only saw the spikes with the addition of a LC filter. There were no unwanted spikes without the filter (and also no sine wave). This led me to believe that filter tuning might be the source of these voltage spikes. At the moment my filter design is choosing the cutoff frequency at the geometric mean of switching frequency (540 Hz) and output voltage frequency (50 Hz).
fc = sqrt(540*50);
LC = 1/(2*pi*Fc)^2 = 9.4e-07 ~= 1e-06
From this I have selected L = 50e-3 Henry & C = 20e-6 Farads.
This simple filter design works with the Simscape block Converter (3 Phase) but not with the Nsm > 1 for the MMC block I have selected. So I now suspect that filter is not the root cause, especially since I now know that it works with MMC as well but only for Nsm = 1.
II. PWM Generation
I have experimented with different PWM Generation techniques but have obtained similar results from PWM (1) and PWM (2)

Any ideas for the root cause of this behavior would be very helpful for me to move ahead. Thank you.Dear Community,
I have a three phase bi-directional power converter modelled by the Simscape block Modular Multilevel Converter (MMC) set for full bridges. This is controlled by a sinusoidal PWM generator and includes a simple LC filter to filter the inverter’s output and help me see a sine wave at the output. The DC Source is a battery with 1000V. The reference setpoint to the PWM generator is a three phase sine wave generator multiplied with a manual gain block (= 0.565) at the moment (this open loop is intentional while I focus on building the plant model at the moment, and will move on to closed loop controller development in next stages).
My model & parameter file is attached.
In the MMC, when the number of submodules = 1 the inverter output and the filtered output waveforms are as expected. (Image below).

However, when I set number of submodules = 2 or above the inverter output (before being filtered) has huge voltage spikes. The filter manages to smoothen these spikes somewhat but I would like to understand why do the spikes show up at Nsm = 2,3, etc and not at Nsm = 1?

A zoomed in view of the phase-to-phase voltage confirms that the inverter is doing it’s job as expected, just with the addition of very high voltage spikes.

Other things I have considered/ tried:
I. Filter Design
For a considerable duration while working with Nsm = 2, I only saw the spikes with the addition of a LC filter. There were no unwanted spikes without the filter (and also no sine wave). This led me to believe that filter tuning might be the source of these voltage spikes. At the moment my filter design is choosing the cutoff frequency at the geometric mean of switching frequency (540 Hz) and output voltage frequency (50 Hz).
fc = sqrt(540*50);
LC = 1/(2*pi*Fc)^2 = 9.4e-07 ~= 1e-06
From this I have selected L = 50e-3 Henry & C = 20e-6 Farads.
This simple filter design works with the Simscape block Converter (3 Phase) but not with the Nsm > 1 for the MMC block I have selected. So I now suspect that filter is not the root cause, especially since I now know that it works with MMC as well but only for Nsm = 1.
II. PWM Generation
I have experimented with different PWM Generation techniques but have obtained similar results from PWM (1) and PWM (2)

Any ideas for the root cause of this behavior would be very helpful for me to move ahead. Thank you. Dear Community,
I have a three phase bi-directional power converter modelled by the Simscape block Modular Multilevel Converter (MMC) set for full bridges. This is controlled by a sinusoidal PWM generator and includes a simple LC filter to filter the inverter’s output and help me see a sine wave at the output. The DC Source is a battery with 1000V. The reference setpoint to the PWM generator is a three phase sine wave generator multiplied with a manual gain block (= 0.565) at the moment (this open loop is intentional while I focus on building the plant model at the moment, and will move on to closed loop controller development in next stages).
My model & parameter file is attached.
In the MMC, when the number of submodules = 1 the inverter output and the filtered output waveforms are as expected. (Image below).

However, when I set number of submodules = 2 or above the inverter output (before being filtered) has huge voltage spikes. The filter manages to smoothen these spikes somewhat but I would like to understand why do the spikes show up at Nsm = 2,3, etc and not at Nsm = 1?

A zoomed in view of the phase-to-phase voltage confirms that the inverter is doing it’s job as expected, just with the addition of very high voltage spikes.

Other things I have considered/ tried:
I. Filter Design
For a considerable duration while working with Nsm = 2, I only saw the spikes with the addition of a LC filter. There were no unwanted spikes without the filter (and also no sine wave). This led me to believe that filter tuning might be the source of these voltage spikes. At the moment my filter design is choosing the cutoff frequency at the geometric mean of switching frequency (540 Hz) and output voltage frequency (50 Hz).
fc = sqrt(540*50);
LC = 1/(2*pi*Fc)^2 = 9.4e-07 ~= 1e-06
From this I have selected L = 50e-3 Henry & C = 20e-6 Farads.
This simple filter design works with the Simscape block Converter (3 Phase) but not with the Nsm > 1 for the MMC block I have selected. So I now suspect that filter is not the root cause, especially since I now know that it works with MMC as well but only for Nsm = 1.
II. PWM Generation
I have experimented with different PWM Generation techniques but have obtained similar results from PWM (1) and PWM (2)

Any ideas for the root cause of this behavior would be very helpful for me to move ahead. Thank you. three-phase inverter, mmc, pwm generator, spwm, full bridge converter, lc filter, voltage spikes, modular multilevel converter MATLAB Answers — New Questions

​

Tags: matlab

Share this!

Related posts

test one two three four
2025-05-20

test one two three four

Is it possible to make this tiny loop faster?
2025-05-19

Is it possible to make this tiny loop faster?

Solar Wind Battery Hybrid Integration
2025-05-19

Solar Wind Battery Hybrid Integration

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Search

Categories

  • Matlab
  • Microsoft
  • News
  • Other
Application Package Repository Telkom University

Tags

matlab microsoft opensources
Application Package Download License

Application Package Download License

Adobe
Google for Education
IBM
Matlab
Microsoft
Wordpress
Visual Paradigm
Opensource

Sign Up For Newsletters

Be the First to Know. Sign up for newsletter today

Application Package Repository Telkom University

Portal Application Package Repository Telkom University, for internal use only, empower civitas academica in study and research.

Information

  • Telkom University
  • About Us
  • Contact
  • Forum Discussion
  • FAQ
  • Helpdesk Ticket

Contact Us

  • Ask: Any question please read FAQ
  • Mail: helpdesk@telkomuniversity.ac.id
  • Call: +62 823-1994-9941
  • WA: +62 823-1994-9943
  • Site: Gedung Panambulai. Jl. Telekomunikasi

Copyright © Telkom University. All Rights Reserved. ch

  • FAQ
  • Privacy Policy
  • Term

This Application Package for internal Telkom University only (students and employee). Chiers... Dismiss