Simscape fluids error cylinder area parametrization
Hello i am a university student and i am trying to build a hydraulic system for a crane miniature. My hydraulic system has the my defined values but i am getting the error: Error:An error occurred during simulation and the simulation was terminated
Caused by:
[‘test_hydraulics/Solver Configuration1’]: At time 0.498629, one or more assertions are triggered. See causes for specific information.
Liquid volume must be greater than minimum physical volume. The assertion comes from:
Block path: test_hydraulics/Double-Acting Actuator (IL)1
Assert location:
o In between line: 242, column: 5 and line: 242, column: 11 in file: foundation.isothermal_liquid.elements.translational_mechanical_converter
o In between line: 386, column: 17 and line: 395, column: 39 in file: fluids.isothermal_liquid.actuators.double_actuator
I dont know what to do i tried editing the parameters and i noticed that when i change my actuator area paramters from m^2 to cm^2 it works.
Thanks in advance!Hello i am a university student and i am trying to build a hydraulic system for a crane miniature. My hydraulic system has the my defined values but i am getting the error: Error:An error occurred during simulation and the simulation was terminated
Caused by:
[‘test_hydraulics/Solver Configuration1’]: At time 0.498629, one or more assertions are triggered. See causes for specific information.
Liquid volume must be greater than minimum physical volume. The assertion comes from:
Block path: test_hydraulics/Double-Acting Actuator (IL)1
Assert location:
o In between line: 242, column: 5 and line: 242, column: 11 in file: foundation.isothermal_liquid.elements.translational_mechanical_converter
o In between line: 386, column: 17 and line: 395, column: 39 in file: fluids.isothermal_liquid.actuators.double_actuator
I dont know what to do i tried editing the parameters and i noticed that when i change my actuator area paramters from m^2 to cm^2 it works.
Thanks in advance! Hello i am a university student and i am trying to build a hydraulic system for a crane miniature. My hydraulic system has the my defined values but i am getting the error: Error:An error occurred during simulation and the simulation was terminated
Caused by:
[‘test_hydraulics/Solver Configuration1’]: At time 0.498629, one or more assertions are triggered. See causes for specific information.
Liquid volume must be greater than minimum physical volume. The assertion comes from:
Block path: test_hydraulics/Double-Acting Actuator (IL)1
Assert location:
o In between line: 242, column: 5 and line: 242, column: 11 in file: foundation.isothermal_liquid.elements.translational_mechanical_converter
o In between line: 386, column: 17 and line: 395, column: 39 in file: fluids.isothermal_liquid.actuators.double_actuator
I dont know what to do i tried editing the parameters and i noticed that when i change my actuator area paramters from m^2 to cm^2 it works.
Thanks in advance! simscape MATLAB Answers — New Questions