How to set my simulation powergui into continuous mode?
My LLC converter simulation is running well when set the powerGUI into discrete mode but have error when shift it into continous mode.
The error is:
An error occurred while running the simulation and the simulation was terminated
Caused by:
Derivative of state ‘1’ in block ‘LLC_DualCtrl/powergui/EquivalentModel1/State-Space’ at time 0.013000000000000001 is not finite. The simulation will be stopped. There may be a singularity in the solution. If not, try reducing the step size (either by reducing the fixed step size or by tightening the error tolerances)
How to fix this error, the input voltage seems be infinite.My LLC converter simulation is running well when set the powerGUI into discrete mode but have error when shift it into continous mode.
The error is:
An error occurred while running the simulation and the simulation was terminated
Caused by:
Derivative of state ‘1’ in block ‘LLC_DualCtrl/powergui/EquivalentModel1/State-Space’ at time 0.013000000000000001 is not finite. The simulation will be stopped. There may be a singularity in the solution. If not, try reducing the step size (either by reducing the fixed step size or by tightening the error tolerances)
How to fix this error, the input voltage seems be infinite. My LLC converter simulation is running well when set the powerGUI into discrete mode but have error when shift it into continous mode.
The error is:
An error occurred while running the simulation and the simulation was terminated
Caused by:
Derivative of state ‘1’ in block ‘LLC_DualCtrl/powergui/EquivalentModel1/State-Space’ at time 0.013000000000000001 is not finite. The simulation will be stopped. There may be a singularity in the solution. If not, try reducing the step size (either by reducing the fixed step size or by tightening the error tolerances)
How to fix this error, the input voltage seems be infinite. simulink, simulation, power_conversion_control MATLAB Answers — New Questions